Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
The Conometric Concept: Coupling Connection for Immediately Loaded Titanium-Reinforced Provisional Fixed Partial Dentures— A Case Series
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 36 , Issue 3
May/June 2016

Pages 347–354


The Conometric Concept: Coupling Connection for Immediately Loaded Titanium-Reinforced Provisional Fixed Partial Dentures— A Case Series

Marco Degidi, MD, DDS/Diego Nardi, DDS/Adriano Piattelli, MD, DDS


PMID: 27100804
DOI: 10.11607/prd.2428

The aim of this prospective study was to demonstrate the feasibility of the conic coupling connection as a novel approach for the retention of immediately loaded, titanium-reinforced, temporary fixed partial restorations. The patients received a fixed, immediate partial restoration, attached using the conic coupling connection to two implants placed in a fresh extraction socket. Changes in marginal peri-implant bone level or probing depth measurements, biologic or technical complications, and any other adverse event were recorded at yearly follow-ups up to 3 years after implantation. A total of 78 implants placed in 39 patients reached the 3-year follow-up. A trend of bone overgrowth over the implant platform (mean: 0.2 mm) and a complete fill of the vertical gap between the implant platform level and the first point of contact of the bone with the implant surface was seen after the 6-month follow-up. No disconnection of any prosthesis was noted during 3 years of full occlusal function. The results of this study suggest that titanium-reinforced, temporary partial restorations with conic coupling retention supported by immediate implants provide a successful, cost-effective treatment modality.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help